Hi Michael and Bob...

Actually, I am using ICOM 756 PRO III here... CAT is working without
problem.
Basically, there isn't any difference in the code between any ICOM radio
because, CI-V protocol is same for all.
The only difference is in radio address. You can change CI-V address
manually in the radio setup screen in DXLog.

Lately, I discovered one bug in CAT processing received data method, which
is fixed now here and will be OK in 2.0.25.
Problem was one some garbage data is received on CAT port due to RFI
problem.
CAT stops after that, and you can see that DXLog.net.exe process is
consuming too much processor resources.

CI-V transceive is also ON here.
Speed data is 9.600 Bd, 8 bit, N parity, 1 stop bit...

73,
Chris - 9A5K




On Thu, Mar 20, 2014 at 7:15 PM, Bob Wilson, N6TV <n6tv at arrl.net> wrote:

> On Thu, Mar 20, 2014 at 11:06 AM, Michael Grehl,DH6JL <dh6jl at rrdxa.eu
> >wrote:
>
> >  CI-V Trancieve ON
>
>
> Does it work any better if you set CI-V Transceive OFF and set polling rate
> to 100 ms?
>
> 73,
> Bob, N6TV