[DXLog.net - Support] Number Server usage in SO2R (single computer)

9A5K 9a5k at 9a5k.com
Tue Feb 16 08:59:35 CET 2016


Hi Ken.

If you're using server and client connected on same pc to same ip, then
you've created loopback in network.
This means that DXLog will send same message between server and client all
the time.
Server/client setup is intented to use as gateway between two networks.
In this case, I would propose to use broadcast networking instead of
client/server and it will work OK.

73,
Chris - 9A5K



On Tue, Feb 16, 2016 at 8:55 AM, Ken K6MR <k6mr at outlook.com> wrote:

> Did anyone use the serial number server in an SO2R setup this past
> weekend? I set it up before the weekend and had problems so did not use it.
>
> Went back over the setup today and all seems correct. What happens is that
> the logger locks up after logging a Q. All the messages appear to be
> correct.
>
> The info line indicates the serial number is reserved, and messages are
> sent. After entering received data and pressing +, the logger locks up.
> Checking the task manager, the logger is still running (not showing Not
> Responding and some cpu activity showing) but unresponsive to keyboard or
> mouse. No additional messages anywhere. If I kill the program and restart
> it, I can see that the Q was logged ok.
>
> If I disable networking the problem goes away, but of course so does the
> number server. I’m using the loopback address (127.0.0.1) as the server and
> client connect to address.
>
> What am I missing?
>
> Tnx,
>
> Ken K6MR
>
> _______________________________________________
> Support mailing list
> Support at dxlog.net
> http://www.dxlog.net/mailman/listinfo/support
>


More information about the Support mailing list