[DXLog.net - Support] Contest Definition for MULT1 - Not allowing own multiplier?

SM5AJV sm5ajv at qrq.se
Tue Apr 19 19:22:59 CEST 2016


Unfortunately it didn't make it.
My own multiplier JO89 is still counted.

Does it matter where the OWN_MULT_VALID=NO line is put?

73
Ingo SM5AJV


2016-04-19 8:53 GMT+02:00 9A5K <9a5k at 9a5k.com>:

> Hi Ingo.
>
> There is a keyword OWN_MULT_VALID which control this behavior.
>
> Try to add this line:
>
> OWN_MULT_VALID=NO
>
> 73,
> Chris - 9A5K
>
> On Mon, Apr 18, 2016 at 5:24 PM, SM5AJV <sm5ajv at qrq.se> wrote:
>
>> Hi!
>>
>> I am trying to make a custom contest definition for the Swedish domestic
>> contest SSA Månadstest and have got almost everything working. See
>> configuration at the bottom.
>> The contest rules says, that your own GRID is not counted as a multiplier.
>> How do I make dxlog to reject my own multiplier?
>>
>> The Exchange in the contest is:
>>
>>   RST SERIAL-NUMER LOCATOR
>>
>> Example:
>>   599 013 JO89LW
>>
>> You get 2 points for each QSO and a multiplier for each GRID, i.e. first 4
>> positions in the received locator on each band
>>
>> Example:
>> If I am in JO89LW and receives 599 011 JO89JH from SM5XYZ, the JO89 should
>> NOT be counted as a multiplier.
>>
>>
>>
>> 73
>> Ingo SM5AJV / SE5E
>>
>>
>>
>>
>>
>> FILE: SSA_MT.txt
>> #
>> # DXLog.net contest definition file
>> #
>> CONTESTNAME=SSA MT
>> BANDS=80;40
>> MODES=CW;SSB
>> CABRILLO_MODES=CW;PH
>> DOUBLE_QSO=PER_BAND
>> POINTS_TYPE=CALC
>>
>> CFG_MULT=ON
>> CFG_GRID_MANDATORY=YES
>>
>> POINTS_FIELD_BAND_MODE=ALL;DEST->DXCC:^$;ALL;ALL;-1
>>
>> POINTS_FIELD_BAND_MODE=!SOURCE->CONT:^EU$;!DEST->CONT:^EU$;ALL;ALL;-1
>> #POINTS_FIELD_BAND_MODE=ALL;ALL;ALL;ALL;2
>> POINTS_FIELD_BAND_MODE=SOURCE->DXCC:^SM$;DEST->DXCC:^SM$;ALL;ALL;2
>>
>> SCORE=BY_BAND
>> SCORE_DISPLAY=BAND;QSO;DUP;MULT1(GRID);POINTS;AVG
>>
>> DXCC_DB_TYPE=CTY
>> DXCC_DB_FILENAME=CTY.DAT
>>
>> #
>> # MULTS DEFINITIONS
>> #
>>
>> MULT1_TYPE=FX
>> MULT1_FIELD=RECINFO
>> MULT1_DISPLAY=MULT
>> MULT1_COUNT=PER_BAND
>> MULT1_FX=$FIELDVALUE.Substring(0,4)
>>
>> CABRILLO_CONTEST_NAME=SSA-MT
>> CABRILLO_LINE=FREQ{F=R,6, };MODE{F=L,3, };DATE;TIME;MYCALL{F=L,13,
>> };SENT{F=L,3, };NR{F=R,4, };GRID{F=L,6, };CALL{F=L,13, };RCVD1{F=L,4,
>> };RCVD2{F=R,4, };RECINFO
>>
>> WINDOWS_CML_ENABLED=NO
>> WINDOWS_WKD_DXCC_ENABLED=NO
>> WINDOWS_WKD_GRID_ENABLED=NO
>>
>> # Fields definition
>> FIELD_PERIOD_VISIBLE=NO
>> FIELD_NR_VISIBLE=YES
>> FIELD_RCVD_NUMERIC=YES
>> FIELD_RCVD_MANDATORY=YES
>> FIELD_RCVD_COPY=NO
>> FIELD_RCVD_TYPE=NR
>> FIELD_RECINFO_VISIBLE=YES
>> FIELD_RECINFO_NAME=Loc.
>> FIELD_RECINFO_MANDATORY=YES
>> FIELD_RECINFO_MAX_LENGTH=6
>> #FIELD_RECINFO_RGX_CHECK=DEST->RCVD:^[A-R][A-R][0-9][0-9][A-R][A-R]$
>> FIELD_AZ_VISIBLE=NO
>> FIELD_MULT_VISIBLE=YES
>>
>> # CW Messages
>> CW_Message_1 = TEST $MYCALL $MYCALL
>> CW_Message_2 = $SERIAL $EXCHANGE
>> CW_Message_3 = $SERIAL $EXCHANGE
>> CW_Message_4 = $MYCALL
>> CW_Message_5 = $LOGGEDCALL
>> CW_Message_6 = NR?
>> CW_Message_7 = ?
>> CW_Message_INS = $LOGGEDCALL $F2
>> CW_Message_PLUS = $CORRECT ++TU-- $CR $MYCALL
>> _______________________________________________
>> Support mailing list
>> Support at dxlog.net
>> http://www.dxlog.net/mailman/listinfo/support
>>
>
>


More information about the Support mailing list